CIM_UninterruptiblePowerSupply
Capabilities and management of an uninterruptible power supply. The properties of the UPS device indicate when incoming power is trimmed or boosted, and the aggregated information of the batteries, generators, etc. that comprise the device. These individual components (for example, multiple batteries) can also be independently modeled and associated with the UPS.
NameSpace Path
\ROOT\CIMV2
PROPERTYSMS_REPORTCIMTYPEDESCRIPTION
ActiveInputVoltageUInt16ActiveInputVoltage indicates which input voltage range is currently in use. Range 1, 2 or both can be specified using the values 3, 4 or 5, respectively. If the Supply is not currently drawing power, the value 6 ("Neither") can be specified. This information is necessary in the case of a UPS, a subclass of PowerSupply.
AvailabilityUInt16The availability and status of the device. For example, the Availability property indicates that the device is running and has full power (value=3), or is in a warning (4), test (5), degraded (10) or power save state (values 13-15 and 17). Regarding the power saving states, these are defined as follows: Value 13 ("Power Save - Unknown") indicates that the device is known to be in a power save mode, but its exact status in this mode is unknown; 14 ("Power Save - Low Power Mode") indicates that the device is in a power save state but still functioning, and may exhibit degraded performance; 15 ("Power Save - Standby") describes that the device is not functioning but could be brought to full power 'quickly'; and value 17 ("Power Save - Warning") indicates that the device is in a warning state, though also in a power save mode.
CaptionStringThe Caption property is a short textual description (one-line string) of the object.
ConfigManagerErrorCodeUInt32Indicates the Win32 Configuration Manager error code. The following values may be returned: 0 This device is working properly. 1 This device is not configured correctly. 2 Windows cannot load the driver for this device. 3 The driver for this device might be corrupted, or your system may be running low on memory or other resources. 4 This device is not working properly. One of its drivers or your registry might be corrupted. 5 The driver for this device needs a resource that Windows cannot manage. 6 The boot configuration for this device conflicts with other devices. 7 Cannot filter. 8 The driver loader for the device is missing. 9 This device is not working properly because the controlling firmware is reporting the resources for the device incorrectly. 10 This device cannot start. 11 This device failed. 12 This device cannot find enough free resources that it can use. 13 Windows cannot verify this device's resources. 14 This device cannot work properly until you restart your computer. 15 This device is not working properly because there is probably a re-enumeration problem. 16 Windows cannot identify all the resources this device uses. 17 This device is asking for an unknown resource type. 18 Reinstall the drivers for this device. 19 Your registry might be corrupted. 20 Failure using the VxD loader. 21 System failure: Try changing the driver for this device. If that does not work, see your hardware documentation. Windows is removing this device. 22 This device is disabled. 23 System failure: Try changing the driver for this device. If that doesn't work, see your hardware documentation. 24 This device is not present, is not working properly, or does not have all its drivers installed. 25 Windows is still setting up this device. 26 Windows is still setting up this device. 27 This device does not have valid log configuration. 28 The drivers for this device are not installed. 29 This device is disabled because the firmware of the device did not give it the required resources. 30 This device is using an Interrupt Request (IRQ) resource that another device is using. 31 This device is not working properly because Windows cannot load the drivers required for this device.
ConfigManagerUserConfigBooleanIndicates whether the device is using a user-defined configuration.
CreationClassNameStringCreationClassName indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and its subclasses to be uniquely identified.
DescriptionStringThe Description property provides a textual description of the object.
DeviceIDStringDeviceID is an address or other identifying information to uniquely name the logical device.
ErrorClearedBooleanErrorCleared is a boolean property indicating that the error reported in LastErrorCode property is now cleared.
ErrorDescriptionStringErrorDescription is a free-form string supplying more information about the error recorded in LastErrorCode property, and information on any corrective actions that may be taken.
EstimatedChargeRemainingUInt16An estimate of the percentage of full charge remaining for a UPS (that uses battery technology).
EstimatedRunTimeUInt32EstimatedRunTime is an estimate in minutes of the time to battery, generator, ... depletion under the present load conditions if the utility power is off, or lost and remains off.
InstallDateDateTimeThe InstallDate property is datetime value indicating when the object was installed. A lack of a value does not indicate that the object is not installed.
IsSwitchingSupplyBooleanBoolean indicating that the power supply is a switching (vs. linear) supply.
LastErrorCodeUInt32LastErrorCode captures the last error code reported by the logical device.
NameStringThe Name property defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property.
PNPDeviceIDStringIndicates the Win32 Plug and Play device ID of the logical device. Example: *PNP030b
PowerManagementCapabilitiesUInt16Indicates the specific power-related capabilities of the logical device. The array values, 0="Unknown", 1="Not Supported" and 2="Disabled" are self-explanatory. The value, 3="Enabled" indicates that the power management features are currently enabled but the exact feature set is unknown or the information is unavailable. "Power Saving Modes Entered Automatically" (4) describes that a device can change its power state based on usage or other criteria. "Power State Settable" (5) indicates that the SetPowerState method is supported. "Power Cycling Supported" (6) indicates that the SetPowerState method can be invoked with the PowerState input variable set to 5 ("Power Cycle"). "Timed Power On Supported" (7) indicates that the SetPowerState method can be invoked with the PowerState input variable set to 5 ("Power Cycle") and the Time parameter set to a specific date and time, or interval, for power-on.
PowerManagementSupportedBooleanBoolean indicating that the Device can be power managed - ie, put into a power save state. This boolean does not indicate that power management features are currently enabled, or if enabled, what features are supported. Refer to the PowerManagementCapabilities array for this information. If this boolean is false, the integer value 1, for the string, "Not Supported", should be the only entry in the PowerManagementCapabilities array.
Range1InputFrequencyHighUInt32The frequency (in Hertz) at the high end of this powersupply's input frequency range 1. A value of zero implies DC.
Range1InputFrequencyLowUInt32The frequency (in Hertz) at the low end of this powersupply's input frequency range 1. A value of zero implies DC.
Range1InputVoltageHighUInt32If the voltage (in Millivolts) rises above the value specified by Range1InputVoltageHigh property, the UPS will compensate by trimming the voltage. A value of 0 indicates that the voltage at which trimming occurs is 'unknown'.
Range1InputVoltageLowUInt32If the voltage (in Millivolts) drops below the value specified by Range1InputVoltageLow property, the UPS will compensate by boosting the voltage using its power source(s). A value of 0 indicates that the voltage at which boosting occurs is 'unknown'.
Range2InputFrequencyHighUInt32The frequency (in Hertz) at the high end of this powersupply's input frequency range 2. A value of zero implies DC.
Range2InputFrequencyLowUInt32The frequency (in Hertz) at the low end of this powersupply's input frequency range 2. A value of zero implies DC.
Range2InputVoltageHighUInt32If the voltage (in Millivolts) rises above the value specified by Range2InputVoltageHigh property, the UPS will compensate by trimming the voltage. A value of 0 indicates that the voltage at which trimming occurs is 'unknown'.
Range2InputVoltageLowUInt32If the voltage (in Millivolts) drops below the value specified by Range2InputVoltageLow property, the UPS will compensate by boosting the voltage using its power source(s). A value of 0 indicates that the voltage at which boosting occurs is 'unknown'.
RemainingCapacityStatusUInt16The indication of the capacity remaining in the UPS' batteries, generator, ... A value of "Normal" (2) indicates that the remaining estimated minutes of run-time is greater than the UPS' defined 'low power' state (typically two minutes). A value of "Low" (3) indicates that the remaining estimated minutes of run-time is less than or equal to the UPS' defined 'low power' state. A value of "Depleted" (4) indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent).
StatusStringThe Status property is a string indicating the current status of the object. Various operational and non-operational statuses can be defined. Operational statuses are "OK", "Degraded" and "Pred Fail". "Pred Fail" indicates that an element may be functioning properly but predicting a failure in the near future. An example is a SMART-enabled hard drive. Non-operational statuses can also be specified. These are "Error", "Starting", "Stopping" and "Service". The latter, "Service", could apply during mirror-resilvering of a disk, reload of a user permissions list, or other administrative work. Not all such work is on-line, yet the managed element is neither "OK" nor in one of the other states.
StatusInfoUInt16StatusInfo is a string indicating whether the logical device is in an enabled (value = 3), disabled (value = 4) or some other (1) or unknown (2) state. If this property does not apply to the logical device, the value, 5 ("Not Applicable"), should be used.
SystemCreationClassNameStringThe scoping System's CreationClassName.
SystemNameStringThe scoping System's Name.
TimeOnBackupUInt32TimeOnBackup indicates the elapsed time in seconds since the UPS last switched to battery power, generator, ... Or, the time since the UPS was last restarted, whichever is less. Zero shall be returned if the UPS is 'on line'.
TotalOutputPowerUInt32Represents the total output power of the power supply in Milliwatts. 0 denotes 'unknown'.
TypeOfRangeSwitchingUInt16TypeOfRangeSwitching describes the kind of input voltage range switching implemented in this power supply. For example, Autoswitch can be specified (value=4).